Error Code tE1
Outlet thermistor (blower housing) open or shorted — Temperature sensor error 1. Displayed during drying cycle or test mode.
Moderate
Address soon - your appliance may not work properly
Also displayed as: tE1
What This Means
Outlet thermistor open or shorted; Harness connector at NA6 pin loose or disconnected; Defective main PCB
How to Fix
- 1
Enter diagnostic test mode: unit in standby, press Power, then press More Time and Less Time simultaneously for 0.5 seconds
- 2
Press START/PAUSE once to advance to thermistor check step
- 3
Turn off power and disconnect dryer before measuring resistance
- 4
Remove NA6 connector from the controller
- 5
Short pin 2 (Blue Wire) and pin 3 (Orange Wire) of the NA6 connector together with a metal jumper
- 6
If controller shows no error with pins shorted: check that NA6 connector and 6-pin harness are properly connected to controller; if OK, replace controller
- 7
If short test does not clear fault: separate harness from thermistor assembly connector and measure resistance between thermistor terminals
- 8
Compare measured resistance to Table 1 values: at 50°F (10°C) expect 18.0 kΩ, at 70°F (21°C) expect 11.7 kΩ, at 90°F (32°C) expect 7.7 kΩ, at 104°F (40°C) expect 6.2 kΩ
- 9
If resistance is out of range, replace thermistor assembly
- 10
If resistance is in range, check and reseat harness-linking connector between thermistor and controller
Other Error Codes for DLEX5000V
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Modem is abnormal. Displayed in test mode only.
Humidity sensor failure.
Wi-Fi module abnormal. Displayed in test mode only.
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.