Error Code EE
EEPROM operation abnormal. Displayed in test mode only.
Moderate
Address soon - your appliance may not work properly
Also displayed as: EE
What This Means
Main PCB EEPROM failure
How to Fix
- 1
Enter diagnostic test mode to confirm EE code
- 2
Power cycle the dryer completely (unplug for 30 seconds, replug)
- 3
Re-enter diagnostic test mode; if EE persists, the main PCB has a faulty EEPROM
- 4
Replace main PCB assembly
- 5
Use anti-static precautions when handling the PCB (wrist strap or repeated ground touch)
Other Error Codes for DLGX5001W
Humidity sensor failure.
Wi-Fi module abnormal. Displayed in test mode only.
Steam generator thermistor open or shorted. Displayed in test mode only.
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.
FlowSense duct blockage at approximately 95% — critically restricted. Error displayed for 2 hours.