Error Code d80
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.
Moderate
Address soon - your appliance may not work properly
Also displayed as: d80
What This Means
Ductwork too long or has too many bends/turns; Significant lint buildup in ductwork; External vent restriction
How to Fix
- 1
Do not use dryer until exhaust is inspected
- 2
Check outside dryer vent hood while dryer is operating for strong airflow
- 3
Inspect ductwork for lint buildup; clean thoroughly
- 4
Check for crushed or damaged flexible transition duct and replace if needed
- 5
Reduce duct run length or number of elbows if excessive
- 6
Remove any debris blocking vent hood
- 7
After cleaning, run AIR DRY cycle and confirm FLOW SENSE indicator remains dark
- 8
If FLOW SENSE LED remains on after cleaning, repair or reroute exhaust system
This Error Applies To
LG DLEX5000V Series Dryers (2017) (2017–present)
Related Error Codes
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
Humidity sensor failure.
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
FlowSense duct blockage at approximately 95% — critically restricted. Error displayed for 2 hours.
NFC module open or shorted. Displayed in test mode only.