Error Code E5
Water supply pump AD value below 10 in test mode — pump failure or wiring fault.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E5
What This Means
DC water supply pump failed or disconnected; Harness wire to pump connector loose or disconnected
How to Fix
- 1
Activate diagnostic test mode and press START/PAUSE four times.
- 2
Wait for each test step to complete before advancing — rapid pressing can damage main board.
- 3
Read the AD value on the display.
- 4
If AD value is 10 or above: pump is normal.
- 5
If AD value is below 10 (E5 displayed): check harness connection between wiring harness and DC pump connector — reseat connectors.
- 6
If connector is secure and E5 persists: replace the DC water supply pump assembly.
This Error Applies To
LG DLEX5000V Series Dryers (2017) (2017–present)
Related Error Codes
Steam generator thermistor open or shorted. Displayed in test mode only.
EEPROM operation abnormal. Displayed in test mode only.
Modem is abnormal. Displayed in test mode only.
Steam generator thermistor error — displayed in test mode only.
Humidity sensor failure.
FlowSense duct restriction at approximately 80% blockage — displayed after drying cycle.
FlowSense duct blockage at approximately 95% — critically restricted. Error displayed for 2 hours.
NFC module open or shorted. Displayed in test mode only.