Error Code dE
Door open or door switch abnormal. During normal operation displays when door is opened mid-cycle. In test mode indicates door switch fault.
Moderate
Address soon - your appliance may not work properly
What This Means
Door not fully latched; Door switch defective; Door switch wiring harness disconnected or damaged
How to Fix
- 1
Enter diagnostic mode (Power + More Time + Less Time simultaneously)
- 2
Press START/PAUSE once — dryer tumbles without heat
- 3
Open door — dE code and chime (7 times) should appear and drum light should come on
- 4
If dE does not appear and light does not come on, proceed to mechanical test
- 5
Disconnect WH1 and BL3 connectors from main PCB
- 6
Measure resistance between WH6 pin 6 (GN) and chassis ground screw — must be less than 1 Ohm
- 7
If resistance is not less than 1 Ohm, check all wiring harness connections and ground screws
- 8
If resistance is less than 1 Ohm, disconnect BL2 and WH4 connectors from main PCB
- 9
Measure resistance between BL2-1 (WH) and WH4-1 (YL): must be less than 1 Ohm with door closed and infinity (open) with door open
- 10
If readings are incorrect, replace door switch
- 11
If readings are correct, replace main PCB
- 12
For drum light check: measure resistance between WH4-2 (YL) and WH4-4 (BK) — less than 1 Ohm with door open, infinity with door closed; if not, replace light bulb or light socket
Other Error Codes for DLGX6701W
Temperature sensor error 1 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
Steam water supply error — DC pump AD value is less than 10 in diagnostic test mode.
FlowSense duct blockage 80% — ductwork approximately 80% blocked. Error displayed for 2 hours only.
FlowSense duct blockage 95% — ductwork approximately 95% blocked. Error displayed for 2 hours only.
Temperature sensor error 2 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
Steam generator thermistor open or shorted. Displayed only in diagnostic test mode.
FlowSense duct blockage 90% — ductwork approximately 90% blocked. Error displayed for 2 hours only.