Error Code tE4
Steam generator thermistor open or shorted. Displayed only in diagnostic test mode.
Moderate
Address soon - your appliance may not work properly
What This Means
Steam generator thermistor open or shorted; Defective steam generator assembly
How to Fix
- 1
Enter diagnostic test mode (Power + More Time + Less Time simultaneously for 0.5 seconds)
- 2
Press START/PAUSE 4 times to reach steam test step
- 3
Verify tE4 code appears
- 4
Inspect steam generator thermistor wiring and connector
- 5
If thermistor wiring is intact, replace steam generator assembly
This Error Applies To
LG DLEX6700B Series Dryers (2022) (2022–present)
Related Error Codes
Door open or door switch abnormal. During normal operation displays when door is opened mid-cycle. In test mode indicates door switch fault.
Temperature sensor error 1 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
Steam water supply error — DC pump AD value is less than 10 in diagnostic test mode.
FlowSense duct blockage 80% — ductwork approximately 80% blocked. Error displayed for 2 hours only.
FlowSense duct blockage 95% — ductwork approximately 95% blocked. Error displayed for 2 hours only.
Temperature sensor error 2 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
FlowSense duct blockage 90% — ductwork approximately 90% blocked. Error displayed for 2 hours only.