Error Code tE1
Temperature sensor error 1 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
Moderate
Address soon - your appliance may not work properly
What This Means
Outlet thermistor open or shorted; Harness connector between thermistor and PCB loose or disconnected; Defective main PCB
How to Fix
- 1
Turn off dryer and disconnect from power
- 2
Remove NA6 connector from main PCB
- 3
Short pin 1 (Blue wire) and pin 2 (Orange wire) of NA6 connector with a metal jumper
- 4
If controller now responds correctly, check that NA6 connector and the 6-pin connector are connected to controller
- 5
If controller still does not respond, replace controller
- 6
If short test fails, disconnect harness from thermistor assembly connector
- 7
Measure resistance between thermistor terminals; compare to Table 1: 50°F=18.0kΩ, 60°F=14.2kΩ, 70°F=9.3kΩ, 80°F=11.7kΩ, 90°F=7.7kΩ, 100°F=6.2kΩ, 110°F=5.2kΩ, 120°F=4.3kΩ, 130°F=2.9kΩ, 140°F=3.0kΩ, 150°F=2.5kΩ, 160°F=2.2kΩ
- 8
If resistance is out of table range, replace thermistor
- 9
If resistance is within table range, check harness-linking connector for damage or corrosion
This Error Applies To
LG DLEX6700B Series Dryers (2022) (2022–present)
Related Error Codes
Door open or door switch abnormal. During normal operation displays when door is opened mid-cycle. In test mode indicates door switch fault.
Steam water supply error — DC pump AD value is less than 10 in diagnostic test mode.
FlowSense duct blockage 80% — ductwork approximately 80% blocked. Error displayed for 2 hours only.
Steam generator thermistor open or shorted. Displayed only in diagnostic test mode.
FlowSense duct blockage 95% — ductwork approximately 95% blocked. Error displayed for 2 hours only.
Temperature sensor error 2 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
FlowSense duct blockage 90% — ductwork approximately 90% blocked. Error displayed for 2 hours only.