Error Code PS

Power supply wire connection wrong or loose (electric dryer only)

Moderate

Address soon - your appliance may not work properly

Also displayed as: PS

How to Fix

  1. 1

    Note: PS error applies to electric dryer (DLEX) only.

  2. 2

    Disconnect power to the dryer.

  3. 3

    Inspect terminal block wire color orientation: Black (L1), White (Neutral/center), Red (L2).

  4. 4

    Verify that the Neutral (White) wire matches the center N terminal on the terminal block.

  5. 5

    Check that the Black and Red wires are connected to the left and right terminal block screws respectively.

  6. 6

    Inspect the Tab Relay connector housing colors: Yellow wire to Black housing (Tab Relay 1); Blue wire to White housing (Tab Relay 2).

  7. 7

    Verify Tab Relay 1 (black housing) connects to black tab relay and Tab Relay 2 (white housing) connects to white tab relay.

  8. 8

    Incorrect or crossed Tab Relay connections can result in heater lockout (Power Off condition).

  9. 9

    Re-seat all terminal block connections and tighten securely.

  10. 10

    Restore power and verify PS error is cleared.

Need more help with your LG DLGX7601BE?