Error Code PS
Power supply wire connection wrong or loose (electric dryer only)
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
Note: PS error applies to electric dryer (DLEX) only.
- 2
Disconnect power to the dryer.
- 3
Inspect terminal block wire color orientation: Black (L1), White (Neutral/center), Red (L2).
- 4
Verify that the Neutral (White) wire matches the center N terminal on the terminal block.
- 5
Check that the Black and Red wires are connected to the left and right terminal block screws respectively.
- 6
Inspect the Tab Relay connector housing colors: Yellow wire to Black housing (Tab Relay 1); Blue wire to White housing (Tab Relay 2).
- 7
Verify Tab Relay 1 (black housing) connects to black tab relay and Tab Relay 2 (white housing) connects to white tab relay.
- 8
Incorrect or crossed Tab Relay connections can result in heater lockout (Power Off condition).
- 9
Re-seat all terminal block connections and tighten securely.
- 10
Restore power and verify PS error is cleared.
Other Error Codes for DLGX7601VE
EEPROM error
Thermistor of blower housing open or shorted
Thermistor of blower housing open or shorted (secondary)
Door switch abnormal
FlowSense - ductwork 90-95% blocked
FlowSense - ductwork restriction detected (80% blocked)
Thermistor of steam generator open or shorted
Power failure or incorrect power supply