LG DLGX7601WEDryer
Error Code E5
Pump (DC motor) failure
Moderate
Address soon - your appliance may not work properly
Also displayed as: E5
How to Fix
- 1
Activate diagnostic test mode
- 2
Press START/PAUSE 4 times to reach mist valve/water supply valve test step
- 3
Read AD value displayed: if above 10, pump is normal; if below 10, E5 error
- 4
Replace DC pump motor assembly (steam system)
Other Error Codes for DLGX7601WE
EE
EEPROM error
tE1
Thermistor of blower housing open or shorted
tE2
Thermistor of blower housing open or shorted (secondary)
dE
Door switch abnormal
d90
FlowSense - ductwork 90-95% blocked
d80
FlowSense - ductwork restriction detected (80% blocked)
tE4
Thermistor of steam generator open or shorted
PF
Power failure or incorrect power supply