Error Code tC

Your dryer's temperature sensor isn't reading correctly

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC

What This Means

Clogged case filter restricting airflow and causing abnormal temperature readings; Thermistor 1 resistance out of range (open or shorted); Wiring harness fault between thermistor and main PBA

What actually causes this:

Usually a clogged lint screen or blocked exhaust vent — restricted airflow causes the sensor to misread temperatures.

First Thing to Check

Pull out the lint screen and clean off all the lint, then check that your exhaust vent hose isn't kinked or blocked.

Parts Involved

Thermistor 1 (2P-Blue Wire)Case Filter

How to Fix

  1. 1

    1. Clean the case filter thoroughly

  2. 2

    2. Measure Thermistor 1 resistance: should be 50KOhm at 25C (77F)

  3. 3

    3. Check wiring harness between Thermistor 1 and main PBA for loose or damaged connectors

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor