Error Code HC
Your dryer isn't heating properly or is overheating
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: HC
What This Means
Restricted airflow causing compressor to overheat; Refrigerant system problem; Compressor mechanical failure; Heat exchanger severely clogged; Ambient temperature too high for heat pump operation
What actually causes this:
Most often caused by a clogged exhaust vent that traps hot air inside the dryer, or the heating element has burned out.
First Thing to Check
Check your exhaust vent — disconnect it from the back of the dryer and look for lint buildup inside.
Parts Involved
How to Fix
- 1
1. Call for service immediately
- 2
2. Check heat exchanger for severe clogging
- 3
3. Check lint filter and duct system for restrictions
- 4
4. Verify ambient temperature is within operating range
- 5
5. Check compressor top thermistor: 200 kOhm +/-3% at 25 degrees C
- 6
6. If compressor is mechanically failed, replace compressor assembly