Error Code tC5

A secondary temperature sensor is giving bad readings

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC5

What This Means

Clogged lint screen restricting airflow; Restricted vent system causing heat buildup; Thermistor 2 resistance out of range (open or shorted)

What actually causes this:

Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.

First Thing to Check

Clean the lint screen thoroughly and make sure the exhaust vent path is clear.

Parts Involved

Thermistor 2Lint ScreenExhaust Vent

How to Fix

  1. 1

    1. Check and clean the lint screen

  2. 2

    2. Check if the vent system is restricted

  3. 3

    3. Measure thermistor 2 resistance: should be 238.23K Ohm at 25 deg C (77 deg F)

  4. 4

    4. If thermistor resistance is out of range, replace the thermistor