Error Code d95
FlowSense duct blockage – ductwork is approximately 95% blocked (displayed for 2 hours after cycle ends)
Moderate
Address soon - your appliance may not work properly
Also displayed as: d95
How to Fix
- 1
Follow all steps for d90 error – blockage is more severe.
- 2
Do not operate dryer until exhaust system is fully cleared and repaired.
- 3
Check outside dryer vent while dryer is operating to confirm strong airflow.
- 4
If exhaust system run is extremely long, have it rerouted to meet maximum duct length requirements.
- 5
Opening the door or pressing POWER button will clear the display, but the underlying restriction must be corrected.
This Error Applies To
LG DLE8400VE Series Dryers
Related Error Codes
Temperature sensor (thermistor) failure – thermistor shorted
No power / power cord not connected correctly (electric dryer only)
FlowSense duct blockage indicator – four bars shown during drying cycle or 'dso' shown after drying; significant ductwork restriction detected
Temperature sensor (thermistor) failure – thermistor open circuit
Humidity sensor (electrode/moisture sensor) failure
Power supply error – electric dryer power cord not connected correctly or house power supply is incorrect / insufficient voltage (below 240V on L1-L2 leg reaching PCB)
Gas supply failure – gas not being supplied to the dryer (gas model only)
Steam pump failure – pump AD (analog-to-digital) value below 10 during diagnostic test (steam models)