LG Dryers

Error Code tE1

Temperature sensor (thermistor) failure – thermistor open circuit

Moderate

Address soon - your appliance may not work properly

Also displayed as: tE1

How to Fix

  1. 1

    Power off the dryer.

  2. 2

    Remove the NA6 connector from the main PCB.

  3. 3

    Short pin 4 (Blue Wire) and pin 5 (Orange Wire) on the NA6 connector using a metal jumper.

  4. 4

    If the error clears when shorted, the thermistor circuit is broken – proceed to thermistor resistance check.

  5. 5

    Measure resistance between thermistor assembly terminals (with harness disconnected). Compare to Table 1: 50°F/10°C=18.0kΩ, 60°F/16°C=14.2kΩ, 70°F/27°C=9.3kΩ, 80°F/21°C=11.7kΩ, 90°F/32°C=7.7kΩ, 100°F/38°C=6.2kΩ, 110°F/43°C=5.2kΩ, 120°F/49°C=4.3kΩ, 130°F/54°C=2.9kΩ, 140°F/60°C=3.0kΩ, 150°F/66°C=2.5kΩ, 160°F/71°C=2.2kΩ.

  6. 6

    If resistance is NOT within Table 1 range → Replace thermistor.

  7. 7

    If resistance IS within Table 1 range → Check harness connector continuity between thermistor and main PCB NA6 connector.

  8. 8

    If harness checks good → Verify NA6 connector is properly seated at the PCB; reconnect firmly. If error persists → Replace main PCB controller.

This Error Applies To

LG DLE8400VE Series Dryers

Service manual exact match: DLE8400VEService manual exact match: DLG8401BEService manual exact match: DLE8400WEService manual exact match: DLG8401VEService manual exact match: DLG8401WE

Need more help with your LG dryers?