Error Code PS
Power supply wire connection wrong or loose (Black-White-Red)
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
Turn off the dryer and unplug from power.
- 2
Check the power cord connection at the terminal block: neutral (white) must connect to center terminal, red and black wires to left and right terminals.
- 3
Verify strain relief is properly tightened and all terminal block nuts are tight.
- 4
For 4-wire connection: confirm green ground wire connects to external ground screw and neutral ground wire of appliance connects to center screw.
- 5
Restore power and retest; if PS persists, check the power supply voltage at the outlet — correct voltage is 208–240 VAC ±10%.
- 6
If outlet voltage is incorrect, have a qualified electrician repair the outlet.
- 7
If outlet is correct and wiring is confirmed correct, check for a blown house fuse or tripped circuit breaker and reset or replace as needed; do not increase fuse capacity.
This Error Applies To
LG DLEX4200B Series Dryers