LG Dryers

Error Code tE2

Thermistor of blower housing - Outlet thermistor open or shorted

Moderate

Address soon - your appliance may not work properly

Also displayed as: tE2

How to Fix

  1. 1

    Turn off the dryer and unplug from power.

  2. 2

    Follow the same diagnostic steps as tE1.

  3. 3

    Disconnect NA6 connector and short yellow and blue pins; if error clears check connector seating, if not replace main PCB.

  4. 4

    Measure thermistor resistance and compare to Thermistor Table 1.

  5. 5

    Replace thermistor if resistance is out of table range; otherwise check harness connectors for damage or loose pins.

This Error Applies To

LG DLEX4200B Series Dryers

Service manual exact match: DLGX4201BService manual exact match: DLEX4000VService manual exact match: DLGX4001WService manual exact match: DLG3601BService manual exact match: DLEX4200BService manual exact match: DLGX4201VService manual exact match: DLEX4000WService manual exact match: DLE3600B+2 more