Error Code dE
Door open or door switch abnormal. During normal operation displays when door is opened mid-cycle. In test mode indicates door switch fault.
Moderate
Address soon - your appliance may not work properly
What This Means
Door not fully latched; Door switch defective; Door switch wiring harness disconnected or damaged
How to Fix
- 1
Enter diagnostic mode (Power + More Time + Less Time simultaneously)
- 2
Press START/PAUSE once — dryer tumbles without heat
- 3
Open door — dE code and chime (7 times) should appear and drum light should come on
- 4
If dE does not appear and light does not come on, proceed to mechanical test
- 5
Disconnect WH1 and BL3 connectors from main PCB
- 6
Measure resistance between WH6 pin 6 (GN) and chassis ground screw — must be less than 1 Ohm
- 7
If resistance is not less than 1 Ohm, check all wiring harness connections and ground screws
- 8
If resistance is less than 1 Ohm, disconnect BL2 and WH4 connectors from main PCB
- 9
Measure resistance between BL2-1 (WH) and WH4-1 (YL): must be less than 1 Ohm with door closed and infinity (open) with door open
- 10
If readings are incorrect, replace door switch
- 11
If readings are correct, replace main PCB
- 12
For drum light check: measure resistance between WH4-2 (YL) and WH4-4 (BK) — less than 1 Ohm with door open, infinity with door closed; if not, replace light bulb or light socket
This Error Applies To
LG DLEX6700B Series Dryers (2022) (2022–present)
Related Error Codes
Temperature sensor error 1 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
Steam water supply error — DC pump AD value is less than 10 in diagnostic test mode.
FlowSense duct blockage 80% — ductwork approximately 80% blocked. Error displayed for 2 hours only.
Steam generator thermistor open or shorted. Displayed only in diagnostic test mode.
FlowSense duct blockage 95% — ductwork approximately 95% blocked. Error displayed for 2 hours only.
Temperature sensor error 2 — outlet thermistor at blower housing is open or shorted. Displayed during drying cycle or test mode.
FlowSense duct blockage 90% — ductwork approximately 90% blocked. Error displayed for 2 hours only.