Error Code PS
Power supply wire connection wrong or loose (electric dryer only)
Moderate
Address soon - your appliance may not work properly
Also displayed as: PS
How to Fix
- 1
Note: PS error applies to electric dryer (DLEX) only.
- 2
Disconnect power to the dryer.
- 3
Inspect terminal block wire color orientation: Black (L1), White (Neutral/center), Red (L2).
- 4
Verify that the Neutral (White) wire matches the center N terminal on the terminal block.
- 5
Check that the Black and Red wires are connected to the left and right terminal block screws respectively.
- 6
Inspect the Tab Relay connector housing colors: Yellow wire to Black housing (Tab Relay 1); Blue wire to White housing (Tab Relay 2).
- 7
Verify Tab Relay 1 (black housing) connects to black tab relay and Tab Relay 2 (white housing) connects to white tab relay.
- 8
Incorrect or crossed Tab Relay connections can result in heater lockout (Power Off condition).
- 9
Re-seat all terminal block connections and tighten securely.
- 10
Restore power and verify PS error is cleared.
This Error Applies To
LG DLEX7600BE Series Dryers (2017) (2017–present)