Error Code E CO
Communication error between main MICOM and display MICOM
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check all loose connections on CON101 and CON5.
- 2
Measure voltage at CON101 pins 18 to 16. Expected: 12V. If not 12V: check hinge connection (loose wiring through hinge). If hinge is OK: replace Main PCB.
- 3
Measure voltage at CON101 pins 10 to 16. Expected: 5V. If not 5V: check hinge connection. If hinge is OK: replace Main PCB.
- 4
Measure voltage at CON101 pins 14 to 16. Expected: not 0V or 5V (variable signal). If 0V or 5V: replace Display PCB.
- 5
Measure voltage at CON101 pins 12 to 16. Expected: not 0V or 5V (variable signal). If 0V or 5V: replace Main PCB.
- 6
Measure voltage at CON5 pins 4 to 3. Expected: not 0V or 5V. If 0V or 5V: replace Display PCB.
- 7
Measure voltage at CON5 pins 5 to 3. Expected: not 0V or 5V. If 0V or 5V: replace Main PCB.
- 8
If all voltages are within spec: explain situation to customer.
This Error Applies To
LG LRFLC2706S Series Refrigerators