LG Refrigerators

Error Code E FS

Freezer sensor error

Moderate

Address soon - your appliance may not work properly

How to Fix

  1. 1

    Check for loose or disconnected connector between Main PCB and freezer sensor at CON8.

  2. 2

    If connector is loose or disconnected: reconnect or repair the connector and retest.

  3. 3

    Measure sensor resistance at CON8 pins 22 to 21. Expected values: -22°F(-30°C)=40kΩ, -13°F(-25°C)=30kΩ, -4°F(-20°C)=23kΩ, 5°F(-15°C)=17kΩ, 14°F(-10°C)=13kΩ, 23°F(-5°C)=10kΩ, 32°F(0°C)=8kΩ.

  4. 4

    If resistance reads 0Ω (short): replace the freezer sensor.

  5. 5

    If resistance reads OL/infinite (open): check sensor connection. If connection is normal, replace the refrigerator PCB.

  6. 6

    If sensor connection is abnormal: reconnect or repair the connector.

  7. 7

    If resistance is within normal range but error persists: explain situation to customer; intermittent fault possible.

This Error Applies To

LG LRFLC2706S Series Refrigerators

Service manual exact match: LRFLC2706S

Need more help with your LG refrigerators?