LG Refrigerators
Error Code F dS
Defrost sensor error
Moderate
Address soon - your appliance may not work properly
How to Fix
- 1
Check for loose or disconnected connector between Main PCB, defrost controller, and sensor at CON8.
- 2
If connector is loose or disconnected: reconnect or repair the connector and retest.
- 3
Measure sensor resistance at CON8 pins 26 to 25. Expected values: 23°F(-5°C)=38kΩ, 32°F(0°C)=30kΩ, 41°F(5°C)=24kΩ, 50°F(10°C)=19.5kΩ, 59°F(15°C)=16kΩ.
- 4
If resistance reads 0Ω (short): replace the defrost sensor.
- 5
If resistance reads OL/infinite (open): replace the refrigerator.
- 6
If resistance is within normal range: explain situation to customer.
This Error Applies To
LG LRFLC2706S Series Refrigerators
Service manual exact match: LRFLC2706S