Error Code E CO
Communication Error — Connection line between Main Control Panel and Display Panel is short or open, or signal transmission fails.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E CO
How to Fix
- 1
Check all connectors for loose connections, especially at door hinge pass-through.
- 2
For Wi-Fi models: measure CON101 voltage in display — pin 16~18: expected 11.5V~12.5V; pin 16~10: expected 5V~7.5V. If absent, replace Main PCB.
- 3
For Wi-Fi models: measure CON101 pin 16~14 in display: should NOT be 0V or 5V. If stuck at 0V or 5V, replace Display PCB.
- 4
For Wi-Fi models: measure CON101 pin 16~12 in display: should NOT be 0V or 5V. If stuck at 0V or 5V, replace Main PCB.
- 5
For non-Wi-Fi models: measure CON101 pins 3~4: expected 11.5V~12.5V. If absent, replace Main PCB.
- 6
For non-Wi-Fi models: measure CON101 pins 24~3 in display: should NOT be 0V or 5V. If stuck, replace Display PCB.
- 7
For non-Wi-Fi models: measure CON101 pins 18~3 in display: should NOT be 0V or 5V. If stuck, replace Main PCB.
- 8
Measure CON5 pins 15~17 on Main PCB: should toggle 0V/5V. If stuck, replace Main PCB.
- 9
Measure CON5 pins 15~18 on Main PCB: should toggle 0V/5V. If stuck, replace Display PCB.
- 10
If all checks pass, explain to customer (possible intermittent hinge wiring issue).
This Error Applies To
LG LRSOC2306 Series Refrigerators
Related Error Codes
Freezer Sensor Abnormal — Freezer sensor short or open failure
UV/Nano LED Module Error — Bad UV LED module or poor connection of display and UV module; caused when feedback signals are abnormal (OPTIONAL feature)
Defrost Heater Abnormal — Defrost heater or thermal fuse short circuit or unplugged connector. Indicated 4 hours after trouble occurs.
Refrigerator Sensor Abnormal — Refrigerator sensor (upper part of refrigerator compartment) short or open failure
Defrost Sensor Abnormal — Defrost sensor short or open failure
Freezer Fan Motor Abnormal — Connection line of the fan motor is faulty, short or open. Display fault when operating fan motor for 65 seconds without feedback.
Ambient (Room) Temperature Sensor Abnormal — Room temperature sensor short or open
Ice Maker Unit (Motor) Abnormal — Ice maker step motor fault, Hall IC fault, or Li-wire short; faulty motor driving circuit. Display shows error if ice maker error occurs within 30 minutes after power on.