Error Code E IK
Ice Maker Unit (Motor) Abnormal — Ice maker step motor fault, Hall IC fault, or Li-wire short; faulty motor driving circuit. Display shows error if ice maker error occurs within 30 minutes after power on.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E IK
How to Fix
- 1
Check CON1 connector between Main PCB and ice maker unit for loose or disconnected condition.
- 2
If connector is loose/disconnected, reconnect or repair the connector.
- 3
Measure ice maker motor (housing) resistance at CON1 pins 26~28: expected 19.7 ohm. If out of range, replace the ice maker unit.
- 4
Push the I/M test key and enter I/M test mode. Measure voltage at CON1 pins 17~18: expected 0~5V (changing). If voltage is not changing between 0~5V, replace Main PCB.
- 5
If voltage is correct but motor does not operate, replace the ice maker unit.
- 6
If all checks pass, explain to customer.
This Error Applies To
LG LRSOC2306 Series Refrigerators
Related Error Codes
Freezer Sensor Abnormal — Freezer sensor short or open failure
UV/Nano LED Module Error — Bad UV LED module or poor connection of display and UV module; caused when feedback signals are abnormal (OPTIONAL feature)
Defrost Heater Abnormal — Defrost heater or thermal fuse short circuit or unplugged connector. Indicated 4 hours after trouble occurs.
Refrigerator Sensor Abnormal — Refrigerator sensor (upper part of refrigerator compartment) short or open failure
Defrost Sensor Abnormal — Defrost sensor short or open failure
Freezer Fan Motor Abnormal — Connection line of the fan motor is faulty, short or open. Display fault when operating fan motor for 65 seconds without feedback.
Ambient (Room) Temperature Sensor Abnormal — Room temperature sensor short or open
Water Tank Switch Error — Water tank not assembled correctly or water tank switch error (optional feature)