Error Code E HS
Defect of humidity sensor — short-circuit or disconnection of humidity sensor
Moderate
Address soon - your appliance may not work properly
Also displayed as: E HS
How to Fix
- 1
Step 1: Check connector between Main PCB and humidity sensor for loose or disconnected harness.
- 2
Step 2: Measure humidity sensor resistance. Compare reading to reference specification.
- 3
Step 3: If resistance is 0 ohm (short circuit), replace the humidity sensor.
- 4
Step 4: If resistance reads OL/infinite (open circuit), replace the humidity sensor.
- 5
Step 5: If resistance is within spec but error persists, replace Main PCB.
This Error Applies To
LG LRYXC2606 Series Refrigerators
Related Error Codes
Defect of refrigerator sensor — short-circuit or disconnection of refrigerator sensor
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defrosting failure — defrost sensor does not reach 40°F (5°C) within 80 minutes after defrost starts. Causes: disconnected thermal fuse, defective defrost heater, defective heater relay, drain tube blockage.
Defect of BLDC fan motor for freezer — no feedback signal from fan motor for more than 65 seconds
Defect of BLDC fan motor for ice compartment — no feedback signal from fan motor for more than 65 seconds. Causes: defect of BLDC motor connection, Drive IC, or TR.
Defect of BLDC fan motor for machine room — no feedback signal from condenser fan motor for more than 65 seconds
Defect of pantry sensor — short-circuit or disconnection of pantry sensor
Defect of ice-room sensor or ice maker sensor — short-circuit or disconnection