Defect of BLDC fan motor for ice compartment — no feedback signal from fan motor for more than 65 seconds. Causes: defect of BLDC motor connection, Drive IC, or TR.

Moderate

Address soon - your appliance may not work properly

Also displayed as: E IF

How to Fix

  1. 1

    Step 1: Reset unit and enter Test Mode 1 (push test button 1 time). Measure fan motor supply voltage at CON4 12th Pin ~ 11th Pin. If NOT 11.4~12.6V, replace Main PCB.

  2. 2

    Step 2: Open freezer door and check for airflow in ice compartment. If windy, proceed to step 5.

  3. 3

    Step 3: If no airflow, manually rotate fan blade by hand. If fan feels sticky/binding, replace fan motor.

  4. 4

    Step 4: Go to step 5.

  5. 5

    Step 5: Measure feedback voltage at CON4 10th Pin ~ 11th Pin. If reads 0V or 5V (not fluctuating), replace fan motor.

  6. 6

    Step 6: Measure PWM voltage at CON4 9th Pin ~ 11th Pin. If reads 0V or 5V (not fluctuating), replace Main PCB.

  7. 7

    Step 7: If all voltages are correct, explain to customer — icing fan is operating normally.