Error Code E PS
PSD (Position Sensor Device) sensor error — malfunction of PSD sensor
Moderate
Address soon - your appliance may not work properly
Also displayed as: E PS
How to Fix
- 1
Step 1: Check connector between Sub PCB and PSD sensor for loose or disconnected connection. If loose, reconnect or repair.
- 2
Step 2: Measure voltage at CON2 5th Pin ~ 7th Pin. Expected: 4.75 ~ 5.25V. If NOT within spec, replace Sub PCB.
- 3
Step 3: Measure signal voltage at CON2 6th Pin ~ 7th Pin. Expected: Not 0 or 5V (oscillating signal). If reads 0V or 5V (static), replace PSD sensor.
- 4
Step 4: If both voltages are correct, reconnect or repair connector and retest.
This Error Applies To
LG LRYXC2606 Series Refrigerators
Related Error Codes
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor
Defect of Mini Cubed ice maker kit — malfunction of Mini Cubed ice maker motor
Defect of refrigerator sensor — short-circuit or disconnection of refrigerator sensor
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defrosting failure — defrost sensor does not reach 40°F (5°C) within 80 minutes after defrost starts. Causes: disconnected thermal fuse, defective defrost heater, defective heater relay, drain tube blockage.
Defect of BLDC fan motor for freezer — no feedback signal from fan motor for more than 65 seconds
Defect of BLDC fan motor for ice compartment — no feedback signal from fan motor for more than 65 seconds. Causes: defect of BLDC motor connection, Drive IC, or TR.
Defect of BLDC fan motor for machine room — no feedback signal from condenser fan motor for more than 65 seconds