Error Code E rt
Defect of room temperature sensor (RT sensor) — short-circuit or disconnection
Moderate
Address soon - your appliance may not work properly
Also displayed as: E rt
How to Fix
- 1
Step 1: Check connector between Main PCB and RT sensor for loose or disconnected harness.
- 2
Step 2: Measure RT sensor resistance. At room temperature (~70°F/21°C), sensor should read approximately 10kΩ.
- 3
Step 3: If resistance is 0 ohm (short circuit), replace the RT sensor.
- 4
Step 4: If resistance reads OL/infinite (open circuit), replace the RT sensor.
- 5
Step 5: If resistance is within spec but error persists, replace Main PCB.
This Error Applies To
LG LRYXC2606 Series Refrigerators
Related Error Codes
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor
Defect of Mini Cubed ice maker kit — malfunction of Mini Cubed ice maker motor
Defect of refrigerator sensor — short-circuit or disconnection of refrigerator sensor
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defrosting failure — defrost sensor does not reach 40°F (5°C) within 80 minutes after defrost starts. Causes: disconnected thermal fuse, defective defrost heater, defective heater relay, drain tube blockage.
Defect of BLDC fan motor for freezer — no feedback signal from fan motor for more than 65 seconds
Defect of BLDC fan motor for ice compartment — no feedback signal from fan motor for more than 65 seconds. Causes: defect of BLDC motor connection, Drive IC, or TR.
Defect of BLDC fan motor for machine room — no feedback signal from condenser fan motor for more than 65 seconds