Error Code E Sd
Sub PCB communication error — communication error between main MICOM and Sub MICOM. Causes: defect of Tx or Rx.
Moderate
Address soon - your appliance may not work properly
Also displayed as: E Sd
How to Fix
- 1
Step 1: Check all loose connections between Sub PCB and Main PCB.
- 2
Step 2: Measure voltage at Sub CON1 8th Pin ~ 33rd Pin. If reads 0V or 5V (not fluctuating), check Sub PCB connection; if connection OK, change Sub PCB.
- 3
Step 3: Measure voltage at Sub CON1 10th Pin ~ 33rd Pin. If reads 0V or 5V (not fluctuating), check Sub PCB connection; if connection OK, change Sub PCB.
- 4
Step 4: Measure voltage at Main CON3 1st Pin ~ 15th Pin. If reads 0V or 5V (not fluctuating), check display PCB connection and change Display PCB.
- 5
Step 5: Measure voltage at Main CON3 3rd Pin ~ 15th Pin. If reads 0V or 5V (not fluctuating), check display PCB connection and change Display PCB.
- 6
Step 6: If all voltages are correct, explain to customer — Sub PCB communication is normal.
This Error Applies To
LG LRYXC2606 Series Refrigerators
Related Error Codes
Defect of freezer craft ice maker sensor — short-circuit or disconnection of craft ice maker sensor
Defect of Mini Cubed ice maker kit — malfunction of Mini Cubed ice maker motor
Defect of refrigerator sensor — short-circuit or disconnection of refrigerator sensor
Defect of freezer sensor — short-circuit or disconnection of freezer sensor
Defrosting failure — defrost sensor does not reach 40°F (5°C) within 80 minutes after defrost starts. Causes: disconnected thermal fuse, defective defrost heater, defective heater relay, drain tube blockage.
Defect of BLDC fan motor for freezer — no feedback signal from fan motor for more than 65 seconds
Defect of BLDC fan motor for ice compartment — no feedback signal from fan motor for more than 65 seconds. Causes: defect of BLDC motor connection, Drive IC, or TR.
Defect of BLDC fan motor for machine room — no feedback signal from condenser fan motor for more than 65 seconds