LG Refrigerators

Error Code E UC

Defect of UVC LED — UVC LED disconnected or UVC LED failure. Check UVC LED connection.

Moderate

Address soon - your appliance may not work properly

Also displayed as: E UC

How to Fix

  1. 1

    Step 1: Check connector between Sub PCB and UVC LED. If disconnected or loose, reconnect or repair connector.

  2. 2

    Step 2: Enable 'Self Care' function. Measure voltage at CON2 14th Pin ~ 13th Pin. Expected: 11.4~12.6V (Self Care ON) or 0~1V (Self Care OFF). If not matching, replace Sub PCB assembly.

  3. 3

    Step 3: Measure voltage at CON2 12th Pin ~ 13th Pin with Self Care ON. Expected: Not 0 or 5 (signal oscillating). If reads 0V or 5V (static), replace UVC LED.

  4. 4

    Step 4: If connector is confirmed good and PCB voltage is correct but UVC LED still fails, replace UVC LED.

  5. 5

    Step 5: If all checks pass, reconnect or repair connector.

This Error Applies To

LG LRYXC2606 Series Refrigerators

Service manual exact match: LRYXC2606SService manual exact match: LRYXC2606VService manual exact match: LRYXC2606BService manual exact match: LRYXC2606D

Need more help with your LG refrigerators?