LG Washers2019–present

Error Code PE

Pressure Sensor Error — pressure sensor assembly is out of order; water level frequency consistently below 10 kHz or over 30 kHz.

Moderate

Address soon - your appliance may not work properly

What This Means

Connector to pressure sensor disconnected or disassembled; Pressure sensor resistance out of range (pin 1 to pin 3 should be 21-23 Ω ±10%); Air chamber or tube clogged; Main PWB assembly defective

How to Fix

  1. 1

    Confirm PE ERROR is displayed.

  2. 2

    Check if connector to pressure sensor is disconnected or disassembled. If YES → reconnect or repair the connector.

  3. 3

    If connector is OK → measure resistance of pressure sensor (pin 1 to pin 3). Expected: 21-23 Ω ±10%. If out of range → replace the pressure switch.

  4. 4

    If resistance is OK → check if air chamber and tube are clogged. If YES → fix the air chamber and remove the foreign material.

  5. 5

    If air chamber is clear → replace the MAIN PWB ASSEMBLY.

  6. 6

    Note: PE error will not clear when START/PAUSE is pressed (unlike other errors) — power will turn off after 20 seconds if PE is not resolved.

This Error Applies To

LG WM3460CW Series Washers (2019) (2019–present)

Service manual exact match: WM3460CWService manual exact match: WM3500CWService manual exact match: WM3460CV