Samsung Dishwashers2019–present

Error Code AC

The main control board and the door control board cannot communicate with each other

Moderate

Address soon - your appliance may not work properly

Also displayed as: No display

What This Means

Main PBA is out of order; Sub PBA is out of order; Communications connection for Main PBA or Sub PBA is not properly connected; Wire harness damaged

What actually causes this:

A power surge or loose wire connection disrupted communication between the control boards

First Thing to Check

Turn off the dishwasher at the circuit breaker, wait 60 seconds, then turn it back on

Parts Involved

Main PBASub PBASub WireCN802 Connector

How to Fix

  1. 1

    1. Check the connections between Main PBA CN802 connector and Display Control Module CN101 connector — reconnect if loose

  2. 2

    2. If check code persists after step 1, replace Sub-Wire

  3. 3

    3. If check code persists after step 2, replace Sub-PBA

  4. 4

    4. If check code persists after step 3, replace Main-PBA

This Error Applies To

Samsung DW80R706 Series Dishwashers (2019) (2019–present)

Service manual exact match: DW80R7060UG/AAService manual exact match: DW80R7060US/AAService manual exact match: DW80R7061US/AAService manual exact match: DW80R7061UG/AC