Samsung Dishwashers2019–present

Error Code AC6

The main control board and the motor control board cannot communicate

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: No display, changes to pause

What This Means

Main PBA is out of order; Inverter PBA is out of order; Communications connection for Main PBA or Inverter PBA not properly connected

What actually causes this:

A loose connector or a power issue disrupted the signal between the main board and the motor controller

First Thing to Check

Turn off the dishwasher at the circuit breaker, wait 60 seconds, then turn it back on

Parts Involved

Inverter PBAMain PBA

How to Fix

  1. 1

    1. Check connections between Main PBA and Inverter PBA connectors — reconnect if loose

  2. 2

    2. Check Inverter PBA for damage or condensation

  3. 3

    3. If connections are good, replace Inverter PBA

  4. 4

    4. If error persists, replace Main PBA

This Error Applies To

Samsung DW80R706 Series Dishwashers (2019) (2019–present)

Service manual exact match: DW80R7060UG/AAService manual exact match: DW80R7060US/AAService manual exact match: DW80R7061US/AAService manual exact match: DW80R7061UG/AC