Samsung Dryers2024–present

Error Code C1

The vent blockage test found a problem with your exhaust

Moderate

Address soon - your appliance may not work properly

Also displayed as: C1

What This Means

Items left inside the drum during Smart Install; Dry sensor (moisture sensor) malfunction; Moisture sensor wiring issue

What actually causes this:

During the Smart Install vent test, the dryer found the exhaust vent is too restricted for safe operation.

First Thing to Check

Check the exhaust vent hose behind the dryer — make sure it's not kinked, crushed, or full of lint.

Parts Involved

Moisture SensorDrum

How to Fix

  1. 1

    1. Remove all items from the drum

  2. 2

    2. Check the dry sensor (moisture sensor bars) for debris or damage

  3. 3

    3. Check moisture sensor wiring connections

  4. 4

    4. Re-run Smart Install

This Error Applies To

Samsung DV25B6900E Series Dryers (2024) (2024–present)

Service manual exact match: DV25B6900EX/ACService manual exact match: DV25B6900E*Service manual exact match: DV25B6900EW/A2