Samsung Dryers2019–present

Error Code tC5

A secondary temperature sensor is giving bad readings

Moderate

Address soon - your appliance may not work properly

Also displayed as: tC5

What This Means

Clogged lint screen restricting airflow; Restricted vent system causing heat buildup; Thermistor 2 resistance out of range (open or shorted); Faulty wiring connection between thermistor 2 and main PCB

What actually causes this:

Similar to the main temperature sensor error — usually caused by lint buildup restricting airflow, or the sensor itself has worn out.

First Thing to Check

Clean the lint screen thoroughly and make sure the exhaust vent path is clear.

Parts Involved

Thermistor 2Lint ScreenExhaust Vent

How to Fix

  1. 1

    1. Check for a clogged lint screen and clean if necessary

  2. 2

    2. Check if the vent system is restricted — inspect exhaust duct

  3. 3

    3. Measure the thermistor 2 resistance: should be 238.23K ohm at 25 deg C (77 deg F)

  4. 4

    4. If thermistor resistance is out of range, replace thermistor 2

  5. 5

    5. Check wiring harness for loose or damaged connections

Parts Commonly Needed for This Error

OEM part numbers confirmed by retailers

This Error Applies To

Samsung DV45R6 Series Dryers (2019) (2019–present)

Service manual exact match: DVE45R6300P/A3Service manual exact match: DVE45R6100C/A3Service manual exact match: DVE45R6100W/A3Service manual exact match: DVG45R6300P/A3Service manual exact match: DVG45R6100C/A3Service manual exact match: DVG45R6100W/A3Service manual exact match: DVE45R6300W/A3Service manual exact match: DVE45R6100P/A3+2 more

Need more help with your Samsung dryers?