Error Code C-70
Steam temperature sensor failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-70
What This Means
Loose connector at main PCB; Loose connector at sensor; Faulty steam temperature sensor; Damaged or broken steam sensor wire harness
What actually causes this:
Loose connector, sensor wire break, or sensor failure
First Thing to Check
Reseat steam sensor connector at main PCB
Parts Involved
How to Fix
- 1
Check whether connector at the main pcb has been inserted
- 2
Check whether connector at the sensor has been inserted
- 3
Measure steam sensor resistance
- 4
Check harness continuity between sensor and main PCB
This Error Applies To
Samsung DOP36C86DL Series Ovens & Ranges
Related Error Codes
Temperature sensor failure - open circuit
PCB over-temperature condition
Steam drain system failure - water not draining
Door lock mechanism failure
Temperature overshoot - sensor or control failure
Temperature probe failure - short circuit
Touch panel communication failure