Error Code C-F0
PCB-to-PCB serial communication failure
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: C-F0
What This Means
Harness disconnection; PCB connector loose; Software version mismatch; PCB failure
What actually causes this:
Loose connector pins, broken communication wire, or incompatible firmware versions
First Thing to Check
Visually inspect connectors CN600 and CNS200 for loose pins
Parts Involved
How to Fix
- 1
Check wire harness between Main PBA CN600 and Sub PBA CNS200
- 2
Check via HASS whether Main-Sub PBA software version is latest
- 3
Verify harness is fully connected at both ends
This Error Applies To
Samsung DOP36P86DLS Series Ovens & Ranges
Related Error Codes
Display/touch panel communication lost
Oven temperature exceeds 650F (343C) or loses heating control
Cooling fan motor unresponsive
Drain pump inactive or water not draining from steam chamber
Meat probe temperature sensor is shorted
Main PCB internal temperature sensor failure
Temperature sensor open or shorted
User control button activated continuously