Error Code C-F0

Communication between Main and Sub PCB is interrupted

Moderate

Address soon - your appliance may not work properly

What This Means

Connector on main PCB not inserted; Connector on sub PCB not inserted; Damaged wire harness between PCBs; Shorted connector pins

How to Fix

  1. 1

    Disconnect power

  2. 2

    Unplug connector on Sub and Main PCB

  3. 3

    Check wire harness between main and Sub PCBs

  4. 4

    Check connector pins on Sub and Main PCB if circuit is shorted

  5. 5

    Repair damaged harness or replace

  6. 6

    Repair the area of the circuit that is shorted

  7. 7

    Replace Sub PCB and Main PCB if needed

This Error Applies To

Samsung NE58H9970W Series Ovens & Ranges (2019) (2019–present)