Samsung Refrigerators2022–present

Error Code 44Er

The inverter board controlling the compressor cannot talk to the main board

Moderate

Address soon - your appliance may not work properly

Also displayed as: 44Er

What This Means

Communication cable between Main PCB and Inverter PCB is loose or damaged; Defective Main PCB; Defective Inverter PCB

What actually causes this:

The compressor drive board and the main control board have lost communication, which means the compressor will not run and the refrigerator will not cool.

First Thing to Check

Unplug the refrigerator and reseat the cable connecting the main board to the inverter board at the back of the unit.

Parts Involved

Main PCBInverter PCBCommunication cable

How to Fix

  1. 1

    Check communication cable connections between Main PCB and Inverter PCB

  2. 2

    Use oscilloscope to verify communication signal

  3. 3

    Confirm 15VDC at C501 (ZD501) and 5VDC at CE1009 on Inverter PCB

  4. 4

    If cable is intact and voltages are correct, replace Inverter PCB

  5. 5

    Replace Main PCB if Inverter PCB replacement does not resolve the error

This Error Applies To

Samsung DRF36C Series Refrigerators (2022) (2022–present)