Samsung Refrigerators2022–present

Error Code COMP-ABNORMAL-CURRENT

Compressor is drawing abnormal current

Moderate

Address soon - your appliance may not work properly

Also displayed as: Inverter LED blink: Abnormal Current Detection pattern

What This Means

Compressor wire CN04 open circuit; Poor solder joint on current sense resistor R1 on Inverter PCB; Compressor winding issue; Refrigeration cycle problem

What actually causes this:

The compressor is drawing too much or irregular current, pointing to a wiring fault, bad solder joint on the control board, or a failing compressor.

First Thing to Check

Check that the compressor connector CN04 is fully seated and undamaged.

Parts Involved

CompressorInverter PCBConnector CN04Shunt resistor R1

How to Fix

  1. 1

    Check compressor connector CN04 for secure connection

  2. 2

    Inspect Inverter PCB for solder defects on R1 and related components

  3. 3

    Check compressor winding resistance

  4. 4

    If wiring and solder are intact, check refrigeration cycle

This Error Applies To

Samsung DRF36C Series Refrigerators (2022) (2022–present)

Service manual exact match: DRF36C500SR/DAService manual exact match: DRF36C500*Service manual exact match: DRF36C**

Need more help with your Samsung refrigerators?