Samsung Refrigerators2022–present

Error Code IPM-FAULT

Power module on the inverter board has detected a fault

Moderate

Address soon - your appliance may not work properly

Also displayed as: Inverter LED blink: SPM Fault pattern

What This Means

IPM module internal fault; Short circuit in compressor phases; Defective Inverter PCB

What actually causes this:

The electronics that drive the compressor motor have detected an internal fault, possibly due to a shorted compressor or failed power module.

First Thing to Check

Check compressor terminals for any short circuit before assuming the inverter board is at fault.

Parts Involved

Inverter PCBIPM moduleCompressor

How to Fix

  1. 1

    Check for shorts between compressor U, V, W terminals

  2. 2

    Check for shorts among IPM pins 1–26

  3. 3

    If no shorts in compressor, replace Inverter PCB

This Error Applies To

Samsung DRF36C Series Refrigerators (2022) (2022–present)

Service manual exact match: DRF36C500SR/DAService manual exact match: DRF36C500*Service manual exact match: DRF36C**

Need more help with your Samsung refrigerators?