Error Code 16
The humidity monitoring sensor is not working
Moderate
Address soon - your appliance may not work properly
Also displayed as: 16
What This Means
Humidity sensor connector disconnected; Humidity sensor defective; Main PCB defect; Water infiltration
What actually causes this:
The sensor wire is loose, got wet, or the sensor failed
First Thing to Check
Check for condensation on the door display — moisture problems may indicate sensor failure
Parts Involved
How to Fix
- 1
1. Check voltage between Main PCB CN30 pins 7 and 8 should be within 4.1V to 0.8V range
- 2
2. Verify connector is fully seated and dry
- 3
3. Inspect sensor for moisture, corrosion, or damage
- 4
4. Replace sensor if defective
This Error Applies To