Error Code 29
The FlexZone defrost heater is not working
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 29
What This Means
CV defrost heater connector disconnected; CV defrost heater burned out or open circuit; Temperature fuse or bimetal opened; Main PCB relay defect
What actually causes this:
The heating element failed or the protection fuse opened
First Thing to Check
Check if frost buildup is visible in the FlexZone — excessive frost indicates defrost failure
Parts Involved
How to Fix
- 1
1. After separating Main PCB CN70 wire, measure resistance between CN70_1-7 and 1
- 2
2. Normal resistance should be 63 ohm (or 230 ohm) ± 7%
- 3
3. 0 ohm indicates heater short — disconnect power immediately
- 4
4. Infinite ohm indicates heater or wire open circuit
- 5
5. Replace heater if out of specification
This Error Applies To
Samsung RF22M9581 Series Refrigerators
Related Error Codes
The freezer fan is not working
The freezer is running colder than normal or the sensor thinks it is
The main control board can't talk to the display
The ice bucket heater is not working
The FlexZone compartment has gotten too warm
The humidity monitoring sensor is not working
The compressor power controller has detected an internal fault
The outdoor temperature sensor is not working