Error Code 83
The compressor is pulling too much electrical current
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 83
What This Means
Compressor motor shorted or jammed; Inverter PCB short circuit; Current sensor defect; Wiring harness shorted to ground
What actually causes this:
The compressor motor is failing or has a short circuit
First Thing to Check
Check if the compressor makes any grinding or unusual noises — that indicates mechanical jam
Parts Involved
How to Fix
- 1
1. Check compressor wire connections for continuity
- 2
2. Verify Inverter PCB soldering has no shorts
- 3
3. Check if any compressor parts are shorted to ground
- 4
4. Measure for excessive current draw
- 5
5. Replace Inverter PCB if wiring is normal
This Error Applies To
Samsung RF22M9581 Series Refrigerators
Related Error Codes
The freezer fan is not working
The freezer is running colder than normal or the sensor thinks it is
The main control board can't talk to the display
The ice bucket heater is not working
The FlexZone compartment has gotten too warm
The humidity monitoring sensor is not working
The compressor power controller has detected an internal fault
The outdoor temperature sensor is not working