Error Code MAIN_INVERTER_COMM_ERROR
Main board and compressor inverter board cannot communicate
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: Error indicated via LED
What This Means
Damaged wiring between main PCB and inverter PCB; Failed Main PCB; Failed Inverter PCB
What actually causes this:
The communication link between the main control board and the inverter that drives the compressor motor has been broken.
First Thing to Check
Check that the cable connecting the main board to the inverter board is properly plugged in at both ends.
Parts Involved
How to Fix
- 1
Check wiring harness between Main PCB and Inverter PCB
- 2
Use oscilloscope to check communication signals on cable
- 3
Replace Main PCB if cable is intact
- 4
Replace Inverter PCB if still failing
This Error Applies To
Samsung RF23M80 Series Refrigerators (2017) (2017–present)
Related Error Codes
Refrigerator compartment defrost sensor is faulty
Compressor is getting too low a voltage to run
Freezer defrost sensor is faulty or not connected
Freezer temperature sensor is faulty or disconnected
Outside air temperature or humidity sensor is faulty
Ice storage room temperature sensor is faulty
Ice storage compartment fan is not working
Ice storage compartment heater is broken