Samsung Refrigerators2010–present

Error Code ⠵–⡄

The compressor has an electrical problem preventing it from starting or running

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: Compressor error indicators range (positions 36–37)

What This Means

Compressor terminal short circuit; IPM (Intelligent Power Module) supply voltage low or high; Inverter PCB soldering defects; Compressor motor stalled or locked; Input power voltage abnormal

What actually causes this:

Input power voltage is wrong or the compressor inverter board has a fault

First Thing to Check

Check that your home voltage matches the refrigerator rating (115V or 230V)

Parts Involved

Compressor NF54M7151AN/E01Inverter PCBMain PBA

How to Fix

  1. 1

    1. Check input voltage at power supply:

  2. 2

    - 115V model: Should be AC 110–127V for 60Hz; AC 220–240V for 50Hz

  3. 3

    - For error: Check AC 60V (low) or AC 155V (high) at input

  4. 4

    2. Check IPM output voltage — must be DC 13.5V or higher

  5. 5

    3. Check compressor connections — ensure terminals are not shorted

  6. 6

    4. Verify inverter PCB soldering — look for cold solder joints

  7. 7

    5. Check resistance of R2 on Main PBA — should be 0.09Ω

This Error Applies To

Samsung RF23R6 Series Refrigerators (2010) (2010–present)

Service manual exact match: RF23R6201AAService manual exact match: RF23R6201EDService manual exact match: RF23R6201AZService manual exact match: RF23R6301AAService manual exact match: RF23R6201BZ