Error Code COMP-IPM-FAULT
Compressor power module has detected an internal fault
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: LED blinks per inverter protection table
What This Means
IPM overcurrent or overtemperature; DC 15V supply below 13.5V; Short circuit on inverter PCB; Compressor winding fault
What actually causes this:
The electronics that drive the compressor detected a dangerous electrical condition and shut it down to prevent damage.
First Thing to Check
Check if the power supply voltage to the compressor board is correct by verifying DC 15V is present.
Parts Involved
How to Fix
- 1
Check DC 15V at ZD501: must be above 13.5V
- 2
Check DC 5V at C1009
- 3
Inspect inverter PCB for solder bridges or burnt components
- 4
Check compressor and cycle for blockage
This Error Applies To
Samsung RF25C5 Series Refrigerators (2022) (2022–present)
Related Error Codes
Refrigerator compartment temperature is abnormally high
Freezer defrost sensor is faulty and cannot detect when defrost is complete
Refrigerator humidity sensor is faulty
External ambient temperature sensor is faulty
Freezer evaporator fan motor is not running
Refrigerator compartment temperature sensor is faulty or disconnected
Ice Bites maker temperature sensor is faulty
Refrigerator compartment fan is not running