Error Code COMP-IPM-SHUTDOWN
Compressor inverter power module has forcibly shut down
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: LED blinks per inverter protection table
What This Means
PCB solder short on inverter circuit; DC 15V output below 13.5V; Compressor or cycle fault
What actually causes this:
The intelligent power electronics protecting the compressor detected a dangerous condition and shut everything down.
First Thing to Check
Unplug the fridge for 10 minutes and try restarting — if it happens again immediately, professional service is required.
Parts Involved
How to Fix
- 1
Check inverter PCB soldering for short circuits
- 2
Verify DC 15V output is above 13.5V
- 3
Check compressor and refrigeration cycle
This Error Applies To