Compressor tried to start but failed due to electrical or mechanical fault

Critical

Stop using immediately - risk of damage or safety issue

Also displayed as: LED blinks per inverter protection table

What This Means

Short between compressor U, V, W phase terminals (CN102); Short among IC3 (IPM) pins 1-24; IPM operating voltage dropped below DC 13.5V; Compressor winding fault; Failed refrigeration cycle (blocked)

What actually causes this:

The compressor could not start, either because of an electrical short, a failed component on the inverter circuit board, or the compressor itself is seized.

First Thing to Check

Unplug the fridge for 10 minutes and plug back in — normal operation resumes if it was a transient fault.

Parts Involved

Inverter compressor NF54M5151ARTT3IPM (Intelligent Power Module) IC3MAIN PCB / Inverter PCBCN102 connector

How to Fix

  1. 1

    Check for short between compressor terminals CN102

  2. 2

    Check IPM voltage — must be above DC 13.5V

  3. 3

    Check for short between IPM pins 1-33

  4. 4

    Inspect inverter PCB soldering for bridged joints

  5. 5

    Check compressor and refrigeration cycle for mechanical blockage