Error Code 44
Compressor cannot receive control signals and may not operate
Critical
Stop using immediately - risk of damage or safety issue
Also displayed as: 44
What This Means
Loose communication cable between boards; Inverter PCB connector failure; Communication bus failure; Main PCB communication circuit fault
What actually causes this:
Inverter communication cable disconnected or inverter board failed
First Thing to Check
Locate and inspect the cable connecting the main board to the inverter board
Parts Involved
How to Fix
- 1
Verify cable connections between main and inverter PCBs
- 2
Check cable for visible damage
- 3
Test communication signal with oscilloscope
- 4
Inspect solder joints on connectors
This Error Applies To
Samsung RF265BEA Series Refrigerators (2016) (2016–present)
Related Error Codes
Freezer defrost cycle cannot detect when ice buildup has melted
Compressor motor is not spinning and cooling system cannot function
Refrigerator defrost cycle cannot detect when ice has melted
Ice storage compartment temperature cannot be monitored
Freezer is warmer than it should be and food may spoil
Compressor cannot operate due to power delivery system fault
Refrigerator voltage is too high and internal components may be damaged